Fire Sentry FS10-RN30 Electro-Optical Fire/Flame Detector 30ft range NonLatching
$ 501.6
- Description
- Size Guide
Description
We have THREE of these Fire Sentry FS10-RN30 Fire/Flame sensors. These were removed from a working facility to be sent back to factory to be re-certified. In the meantime customer could not wait and we installed a new set, so these have been fully certified working from Honeywell as per new specs. They will be shipped in an electrostatic bag and bubble wrap. Only includes the flame sensor itself as pictured, the aluminum housing is NOT included, please make note of that. Also please verify with your installer if these will be compatible with your Fire Alarm system. We cannot accept returns on these as they are very sensitive detectors. Again these have been certified by Honeywell themselves and have been sent back to us as meeting all specs/testing criteria.Below is the details of the units.
-----------------------------------------------------------------------------------------------
FS10-RN30 FS10 Stand Alone (Unitized) Electro-Optical Fire Detector, Alert / Fire Early Warning Relay, 30 ft Sensitivity (Non-Latching Alert & Alarm Relays) by Honeywell Analytics
Our fire detection systems have been protecting electrostatic paint spray booths worldwide - with millions of booth operational hours and not a single fire loss.
Fire Sentry FS System 10™
A high-speed microprocessor based fire detection and process control system specially designed for liquid and powder coating applications, the Fire Sentry FS System 10™ quickly detects the presence of a flame, reacts by initiating a shutdown of the electrostatic finishing process in a matter of milliseconds; and effectively interrupts the fire before residues and wet paint films can ignite.
The Fire Sentry FS System 10 is the only system that provides a two-stage response: an ALERT for spray gun "fireball" type fires and if the fire continues, a FIRE ALARM is declared in 4-5 seconds.
The Fire Sentry FS System 10 is vastly superior to conventional detectors due to the electro-optical quantum infrared sensors array and the ability to accurately detect fires without false alarms. The FS System 10 is available in both wallmount controller and card controller configurations. (For additional information on card controller, consult the factory.)
The detector is mounted in an explosion-proof housing. The wall-mounted controller is a self-contained system mounted in a NEMA 12 enclosure with LCD display and LED status lights. Three 10-amp mechanical relays have been incorporated for shutting down the paint flow, electrostatics and conveyor. Event history and fire tech data are reported by the detector in real time and data, then stored in the controller's non-volatile memory. FirePic™ and SnapShot™ data can be downloaded from the RS-232 port of the controller from your PC. The controller may operate with one or two detectors.
Fire Sentry FS10-R Unitized
The Fire Sentry FS10-R Unitized is a multi-spectral infrared electro-optical flame detector designed specifically for liquid paint or powder spray booth applications. Based on the Fire Sentry FS System 10, the FS10-R Unitized flame detector meets the need for a stand-alone capability and complies with the NFPA 33 Standard. The WideBand IR™, NearBand IR, and Visible sensors combined with the advanced signal procession provide optimum performance. High spend fire response with optional factory sensitivity settings and alarm outputs provide the best, proven solution to fire detection for the Finishing Industry.
Features
Multi-Spectral digital electro-optical infrared fire detector
Meets requirements of NFPA 33
Unique two-stage ALERT and FIRE ALARM response
Immune to false alarms caused by arcs or corona discharges
Built-in automatic "through the lens" self-test
Not sensitive to background radiant energy sources such as paint heaters
Not affected by absorbing smoke or paint solvent mist in liquid pant spray booths
Sees through paint, powder or oil residue on detector's lens
Digital communications with RS-485 interface
FirePic™: retrieval of recorded pre-fire data
SnapShot™: dynamic graphical display of what the detector sees
Applications (indoor use only)
Liquid Paint Spray Lines
Aerosol Filling
Powder Coating Booths
Curing Ovens
Operation
The Fire Sentry FS10-R Unitized detector is designed to operate with any approved fire alarm panel. Interface with fire alarm panel is accomplished using the detector's ALARM, ALERT and FAULT relays.
When power is applied, a self-test is automatically performed and the FAULT relay is energized to show that the detector has no faults. The front LED blinks every ten seconds to indicate normal operation.
In normal operation, the continuous spectral data stream of information from the sensor array is analyzed by the microprocessor. With two distinct relay outputs, the Fire Sentry FS10-R Unitized provides an ALERT output for spray gun "fireball" type fires, and if the fire continues a FIRE ALARM is declared in 4-5 seconds.
The detector stores all the pre-fire spectral data from the sensor array in non-volatile memory for retrieval and evaluation. The Fire Sentry FS10-R stores the last six FirePic™ events, each 8 seconds long; and 200 event histories with time and date stamp. The FirePic data can then be used to postulate the cause of the fire.
Sensitivity
30 ft. to a 1 sq. ft. gasoline fire
Response Time
Alert: 0.3 second (response to "fireball" type fires)
Fire Early Warning: 1 second (early response to a fire alarm)
Fire Alarm: Less than 5 seconds (if fire continues)
Field of View
90° (± 45° horizontal and vertical)
Spectral Sensitivity
Visible: 400 - 700 nanometers
Near Band IR: 0.7 - 1.1 microns
Wide Band IR: 0.7 - 3.5 microns
Input Power
24 VDC nominal (18-32 VDC) - Regulated
Power Consumption
Normal: 85 mA (typical); Alarm: 120 mA (typical)
Output Relays
Alert/Early Warning:
SPST, N.O.
Fire Alarm:
SPST, N.O.
Fault:
SPST, N.O. with no power
Contact ratings: 1 amp @ 24 VDC
Normal Operation
Fault relay is Energized, Non-Latching
All other relays are De-energized
Fire and Alert relays are available
Latching or Non-Latching
Operating Temperature
Operating: -40° to +185°F (-40° to +85°C)
Humidity Range
10% to 90% relative humidity, non-condensing
Enclosure
Not included
Certifications
Explosion-Proof; Class I, Div. 1 & 2, Groups B, C, & D
Class II, Div. 1 & 2, Groups E, F, & G
Class III
FM, CE
Dimensions
4.81 in. diameter; 4.65 in. deep