Victron Autotransformer - Split Phase 120/240V - 100AMP
Victron Autotransformer 120/240V-100A
Brand
Victron Energy
Part Number
ITR000100101
UPC
8719076022428
Description
Shipping
Returns
Autotransformer - Split Phase 120/240V - 100AMP
The Autotransformer: for step up, step down and split phase balancing An autotransformer can be used for step up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention.
Consider for example a 30A 120/240V split phase supply. The supply could be the grid, a generator or two stacked inverters. Some of the loads connected are 240V, others are 120V. On each 120V leg the load should not exceed 30A. The problem is that as soon as 120V loads are connected, the two legs will show a different current. This is because the 120V loads on the two legs will never be balanced. A 120V 1200W hairdryer, for example, will draw 10A from one leg. A 120V washing machine could even draw in excess of 20A from one leg. Between the two legs the difference in current, or current unbalance, will therefore often be 20A or more. This means that the 30A supply will not be used up to its full potential. By the time one leg draws 30A, the other leg may be drawing no more than 10A, and increasing the 240V load, for example, will result in an overload of one leg while the other leg still has spare capacity. Theoretically, the total power that can be drawn from a 30A 120/240V supply is 30 x 240 = 7,2 kVA. In case of 20A unbalance, the practical maximum will be 30 x 120 + 10 x120 = 4,8kVA, or 67% of the theoretical maximum. The solution is an Autotransformer. By leaving the neutral of the split phase supply unused, and connecting an Autotransformer to create a new neutral, as shown in figure 1, any load unbalance is ‘absorbed’ by the Autotransformer. In case of a 30A supply, the load can be increased to 7,2kVA, and a 20A load unbalance will result in one leg supplying 40A, and the other leg 20A. The 20A difference will flow through the neutral and the windings of the Autotransformer. The current through both 120V wires of the split phase supply will be 30A.
Ground relay for use with Multi or Quattro Inverter/Chargers included When operating in inverter mode, the neutral output of the inverter/charger must be connected to ground to guarantee proper functioning of a GFCI. In case of a split phase supply the neutral must be grounded. For this purpose a grounding relay is built in the autotransformer’s enclosure. The relay is controlled by the 230/240V Multi or Quattro. (The internal grounding relay in the 230/240V Multi or Quattro must be disabled)
Temperature protected In case of overheating, the Autotransformer is disconnected from the supply. Reset is manual.
An alternative to stacked inverters The alternative to stacking two 120V inverters to provide a 120/240V split phase supply is a 240V inverter with an additional Autotransformer.
Additional Specs (If Applicable):
Amperage = 100a
FREE Shipping only applies to the Continental 48 States.
There may be additional shipping fees for items going to Hawaii, Alaska, and Puerto Rico. NO PO Boxes with UPS Shipping. Most Items ship out same day if placed before 2 PM Eastern Time. Tracking information will be uploaded into eBay when it has been shipped. You will receive an email from eBay with this notification. Our products ship from Florida, New Jersey, Arizona and occasionally from other warehouses in the United States to ensure package transit times and item availability are optimized. The estimated delivery date from eBay may be inaccurate. We offer discount overnight services for most items using FedEX Next Day Air. FREE Shipping only applies to the Continental 48 States. There may be additional shipping fees for items going to Hawaii, Alaska, and Puerto Rico. NO PO Boxes with UPS Shipping. Most Items ship out same day if placed before 2 PM Eastern Time. Tracking information will be uploaded into eBay when it has been shipped. You will receive an email from eBay with this notification.
We cannot accept the return of software unless it was defective upon receipt.
Please verify that you have the correct product prior to purchasing. Most of our items have a 30 day Return Policy. Non-Defective items must be Returned in the original packaging with all accessories and paperwork. The item must be unused and/or uninstalled. Defective items must be returned without Physical damage. If the item was damaged during shipping, please let us know within 48 hours of receipt. Please contact us prior to shipping an item to us to obtain an RMA number. You may also use the eBay return link.
Listings
Add to Favorites
Contact
Store
© 2020 All Rights Reserved - Alta Boat Parts is a division of Douglas Supply LLC